Back to Overview

Hydraulic crushing hammer does not strike reasons and solutions

Oct 30,2024

One of the main reasons why hydraulic breakers don't work is oil leakage. Oil leakage may cause the hydraulic hammer to be unable to obtain enough oil pressure to work.

I, the hydraulic crushing hammer does not strike the original

There may be a variety of reasons why the hydraulic breaker does not strike, below we will introduce one by one

1. Oil leakage

One of the main reasons why hydraulic breakers don't work is oil leakage. Oil leakage may cause the hydraulic hammer to be unable to obtain enough oil pressure to work. To rule this out, you should look for the cause of the leak in time. It may be rupture of oil pipe, aging of seals, loose pipeline and so on.

2. Oil line blockage

Another common reason for hydraulic breakers not working is blocked oil lines. Clogged oil line may lead to insufficient pressure, so that the crusher can not work! In this case, the clogged oil line should be replaced or cleaned.

3. Piston seal damage

When the hydraulic breaker does not work, there may be piston seal damage If the seal is not tight or damaged, the oil will leak out, thus reducing the pressure. At this point, the piston seal needs to be replaced to ensure that the oil does not leak under pressure

II, the solution of hydraulic crushing hammer not striking

Hydraulic crushing hammer does not strike may affect the productivity, the following are some common solutions

1. Exclude the oil leakage problem

If you find that the hydraulic breaker does not work, please first check whether the oil is leaking or not Once the problem of oil leakage is found, the cause of the problem should be found immediately and solved in time

2. Clean or replace the clogged oil

If the reason why the hydraulic breaker does not work is that the oil circuit is blocked, please clean or replace the oil circuit first to ensure the smooth flow of oil.

3. Replace damaged seals

If the reason why the hydraulic breaker does not work properly is the piston sealing ring, please replace the damaged sealing ring in time. After the seal is installed, a tightness test should be performed to ensure that there is no leakage.

4. Redo the combination of movement

If all of the above measures have been tried but still not effective, it is recommended to redo the combination action of the hydraulic breaker and conduct a pressure test to ensure that the hydraulic breaker can work properly.